PART ONE - Overview of External Wall Insulation

  • 1.1 Why External Wall Insulation?
  • 1.2 House Types
  • Buildings Unsuitable for External Wall Insulation
  • 1.3 Principals of External Wall Insulation
  • 1.4 Terminology and Definitions
  • 1.5 System Types
  • 1.6 Traditional System types currently in use
  • 1.7 Traditional Finishes
  • 1.8 Selecting a System and Producing a Contract
  • 1.9 Costings and Comparisons
  • 1.10 Planning & Building Regulations

PART TWO - System Performance

  • 2 System Performance & Criteria
  • 2.1 Safety
  • 2.2 Thermal Performance
  • 2.3 Wind Loadings
  • 2.4 Condensation Risks
  • 2.5 Impact & Puncture Resistance
  • 2.6 Temperature Tolerance
  • 2.7 Moisture Protection
  • 2.8 Durability
  • 2.9 Appearance
  • 2.10 Detailing
  • 2.11 Mastics & Seals
  • 2.12 Avoidance of Risk

PART THREE - Materials and Components

  • 3.1 Insulation Slabs
  • 3.2 Reinforcing Layers
  • 3.3 Fixings & Fasteners
  • 3.4 Adhesives
  • 3.5 Renders, Coatings and Finishes
  • 3.6 Finish Top Coats
  • 3.7 Natural Hydraulic Lime Renders
  • 3.8 Brick Slips
  • Featured Brick Slip System - Epsibrick
  • Featured Brick Slip System - Eurobrick
  • 3.9 Simulated Brick Render
  • Featured Render System - Brick-Rend
  • 3.10 TRIMS & BEADS
  • Featured Trims - Wemico
  • 3.11 Trim Details
  • Featured Trims - Renderplas
  • Featured Trims - VWS
  • 3.12 Mastics and Sealants
  • 3.13 Render & Component Supply Details

PART FOUR - Design & Detailed Drawings

  • 4.1 Condensation
  • 4.2 Cold bridges
  • 4.3 Heat loss through floors
  • 4.4 Thermal Design of System
  • 4.5 Render Design
  • 4.6 System Design Detailing
  • 4.7 Fire Breaks
  • 4.8 Systems with Drainage or Ventilated Cavities
  • 4.9 Architectural Features
  • 4.10 Terracotta Tiles
  • 4.11 Mouldings
  • 4.12 Block Bonding
  • 4.13 Specifications
  • 4.14 New-Build Systems
  • Featured System by Eurobrick

PART FIVE - Installation & Repairs

  • 5.1 Wall Preparations
  • 5.2 Methods of cleaning & Testing
  • 5.3 Methods of selecting Fixings
  • 5.4 Pre-Installation Preparation
  • 5.5 Pre-Installation of Beads & Trims
  • 5.6 Installation - Insulation boards
  • 5.7 Reinforcements
  • 5.8 Application of Renders
  • 5.9 Simulated Brick-Effect Renders
  • 5.10 Insulated Render - Featured System
  • 5.11 Application of Wet Finishes
  • 5.12 Application of Dry Finishes
  • 5.13 Brick Slips
  • 5.14 Sealants
  • 5.15 Protection of the Works
  • 5.16 Common Problems
  • 5.17 Repair & Maintenance
  • 5.18 Repairing the System
  • 5.19 Attachment of External Components

PART SIX - Application

  • 6.1 Tendering & Design
  • 6.2 Selecting a System
  • 6.3 Selecting a Contractor
  • 6.4 Site Drawings
  • 6.5 Manufacturing Drawings - Special Components
  • 6.6 Site samples
  • 6.7 Pre-Contract
  • 6.8 Material scheduling & Ordering
  • 6.9 Storage of Materials
  • 6.10 Site Inspections
  • 6.11 Site Reports
  • 6.12 Monitoring Job Conditions
  • 6.13 Certification of Completion
  • 6.14 Guarantees
  • 6.15 Owner’s Manual
  • 6.16 Access, Tools & Safety
  • 6.17 COSHH Information

PART SEVEN - Assessors, HIPs & Sustainability

  • 7.1 Energy Assessors
  • 7.2 Code for Sustainable Homes
  • 7.3 Sustainable materials
  • 7.4 Energy Performance of Building Directive
  • 7.5 The National home Energy Rating Scheme
  • 7.6 Thermal Assessments

PART EIGHT - Useful Information

  • 8.1 Directory of Organisations
  • 8.2 Directory of Component suppliers
  • 8.3 Useful Publications
  • 8.4 Systems Currently Certified
  • 8.5 Useful Websites

CD ROM Contents - Detailed Drawings. Reports & Checks

  • General Arrangement
  • Insulation Board Layouts
  • Insulation Corner Details
  • Typical Section Details
  • Rail Fixing Details
  • Fixings Layout
  • Mineral Fibre Mesh Corners
  • Expanded Metal Mesh - Overlaps
  • Base Trim Detail 1
  • Base Trim Detail 2
  • Base Insulation Below DPC
  • System Corner Detail
  • Render Movement Joint
  • Structural Movement Joint 1
  • Structural Movement Joint 2
  • Abutment Detail 1
  • Abutment Detail 2
  • Top Capping Detail 1
  • Top Capping Detail 2
  • Verge Detail 1
  • Verge Detail 2
  • End-Stop Detail 1
  • End-Stop Detail 2
  • Reveal Detail - Uninsulated
  • Reveal Detail - Insulated
  • Reveal Detail - Window Replaced
  • Reveal Detail - Window Repositioned
  • Window Head - No Drip
  • Window Head - With Drip
  • Window Cill - Timber
  • Window Cill - Under-cill
  • Window Cill - Over-cill
  • Window Cill - Detail 1
  • Window Cill - Detail 2
  • Mid-Point Trim Detail
  • Cill Replacements
  • Bandings - External
  • Bandings - Recessed
  • Window Pods
  • Fire Break - Details
  • Fire Break - Layout
  • Brick Slips 1 - Bonds
  • Brick Slips 2 - Soldier Courses
  • Brick Slips 3 - Quoins
  • Brick Slips 4 - Corners
  • Brick Slips 5 - Setting-Out
  • Brick Slips 6 - Pointing Joints
  • System Junction Detail 1
  • System Junction Detail 2
  • Attachment Details
  • Quoin Detail
  • Coping
  • Coping Details
  • Ashlar Cuts
  • Tile Hanging
  • Service Duct 1
  • Service Duct 2
  • Service Duct 3
  • Vertical Boarding
  • Drawing - New-Build
  • Insulation to difficult area 1
  • Insulation to difficult area 2

The drawings above are intended as a guide only, each project may require variations suitable for that particular project.

  • Standard Report Sheet 1 - Pull-Out Test Report
  • Standard Report Sheet 2 - Weather Record Sheet
  • Standard Report Sheet 3 - Certificate of Practical Completion
  • Standard Report Sheet 4 - Owner’s Manual
  • System Check List
  • Design Check List
  • Index of Sub-Headings

Home  |  Synopsis  |  Order